Browse all practice questions for the ESCO Refrigeration Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

ESCO Refrigeration Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What is refrigerant recovery efficiency and why is it important for compliance?
  • Where should the liquid line filter dryer be installed in a typical DX system?
  • What is the function of a metering device in a refrigeration system?
  • When diagnosing a compressor that won't start, which step best aligns with a proper starting-issue checklist?
  • Which gauge is used to measure vacuum at the micron level in HVAC systems?
  • What is the purpose of a micron gauge in vacuum testing of refrigeration systems?
  • Which statement best describes the condenser inlet state?
  • Which parameter does the oil pressure safety switch monitor?
  • A faulty condenser fan motor on an air conditioning system will cause these symptoms...
  • Compared to R22 systems, the flow rate of a thermostatic expansion valve (TEV) in a 410A system is approximately what?
  • Which indicators signal moisture in a refrigeration system and how can moisture compromise performance?
  • In a vacuum of 28 inches of mercury, at what temperature will water begin to vaporize?
  • In the evaporator, latent heat is transferred from the refrigerated space to the refrigerant.
  • The purpose of an evaporator pressure regulating valve (EPR) is to...
  • Which statement about slight suction-line superheat is true?
  • What is the purpose of the receiver in a vapor-compression refrigeration system?
  • How is subcooling measured, and what does it indicate about system performance?
  • Which vacuum level is typically targeted when evacuating a system to remove moisture?
  • Which action best removes solid contaminants after a severe hermetic compressor burnout?
  • A low refrigerant charge in a system using both TEV and capillary tube will cause which pressure change?
  • How should you prevent refrigerant oil from contaminating the suction line and what precautions apply when opening or brazing?
  • Using a manifold gauge set, high-pressure readings primarily indicate which system area?
  • In testing the efficiency of an air-cooled condenser, the refrigerant condensing temperature should be no more than approximately how many degrees higher than the leaving air temperature?
  • Where would a sight glass normally be located in a refrigerant system?
  • Which condition would you expect from an overcharged refrigerant in a capillary tube system?
  • Why is an inline filter-drier used and where is it placed in the system?
  • What is a potential consequence of moisture in a refrigeration system?
  • The evaporator's function is to:
  • What is the state of refrigerant entering the condenser?
  • Why is purging lines with dry nitrogen during brazing important?
  • How can you tell if the condensate drain is blocked and what steps fix it?
  • Which component has no moving parts and is commonly used as a fixed restriction in metering?
  • Differentiating evaporator and condenser coils, where heat transfer occurs and what state changes take place?
  • Capillary tube metering devices are described as which type of restriction?
  • In a pump-down system, where is the solenoid valve located?
  • In the evaporator, latent heat transfer occurs as the refrigerant boils and absorbs heat
  • Between which components is the liquid line filter dryer installed?
  • An inefficient compressor is usually indicated by which combination of head and suction pressures?
  • Which statement describes the function of an oil separator in a refrigeration system?
  • What is the function of the evaporator in a vapor-compression refrigeration system?
  • A TXV has three operating pressures...
  • What is the minimum vertical drop from the outlet of the condensate drain pan to the inlet of the P trap?
  • Which refrigerant is HCFC and commonly used in older residential HVAC systems?
  • If excess refrigerant is charged into a system, the result is typically
  • A thermal-electric (solid state) expansion valve is controlled by
  • What is the typical state of refrigerant in the suction line?
  • The oil pressure safety switch is operated by...
  • What role does cylinder fill percentage play in refrigerant handling and what safety precautions should be followed?
  • Which of the following accurately describes EPA requirements for refrigerant recovery?
  • Water enters a condenser at 80°F and leaves at 100°F; what is the water temperature rise?
  • A decrease in superheat causes the TXV to
  • A system with a leak in the liquid line was repaired, evacuated, and recharged. When started, the compressor is noisy and running hot. The most probable cause is...
  • How does humidity affect evaporator frosting and energy efficiency?
  • In which applications is R-404A typically used?
  • ___ can be used for leak detection with ALL high pressure refrigerants.
  • Which statement correctly describes high-side and low-side pressures and subcooling?
  • Which statement is not true of a capillary tube metering device?
  • In the energy balance example, the heat gained by the water equals the heat lost by the refrigerant.
  • Which fault is most likely to cause high suction pressure and high discharge pressure in an air conditioning system?
  • Which sequence correctly describes how to calculate evaporator outlet superheat?
  • Before servicing a system, what equipment is required to handle refrigerant safely?
  • A partially iced over evaporator can be caused by...
  • Frost on the suction line indicates:
  • The AXV is designed to maintain...
  • In an R134a system, the high pressure gauge reads 143 psig and the liquid line temperature at the condensing unit is 95°F. What is the operating system superheat?
  • How can you tell if a system uses R-410A versus R-22 from labeling and service data, and why does it matter for pressures?
  • Bubbles in the sight glass could indicate which condition in a system using a thermostatic expansion valve?
  • In an air conditioning system that uses a TXV, the evaporator outlet temperature relative to the inlet is usually
  • How does UV dye leak detection work and what color indicates a leak under UV light?
  • Which type of expansion valve is described as solid-state and controlled by an NTC parameter?
  • What is the primary purpose of an accumulator?
  • A mechanical shaft seal is necessary on a...
  • Which condition indicates the presence of frost on the suction line?
  • A rise in evaporator pressure causes the AXV to begin to
  • The first function the condenser must perform is to ___ the refrigerant before condensing can occur.
  • Why is a vacuum applied to the isolated section before re-pressurizing after service?
  • What is the function of a low-pressure switch in a compressor-controlled system and what fault conditions could trigger it?
  • An increase in head pressure causes ___ refrigerant to flow through a capillary tube.
  • What is the purpose of a crankcase heater and when should it be energized?
  • A TXV is designed to maintain...
  • Which statement is not true about capillary tube metering devices?
  • Heat added to a vapor after the change of state is called?
  • If the cut off plate is removed from a blower assembly, how would this effect blower performance?
  • How is superheat adjusted on many metering devices?
  • Which OSHA electrical-safety standards apply to HVAC technicians working on energized equipment?
  • Which oils are commonly used in refrigerant systems, and what steps help prevent cross-contamination when replacing oil?
  • Why is nitrogen or dry purge used during brazing of refrigerant piping?
  • Removing the cut off plate from a blower assembly would most directly affect which parameter?
  • Which statement best describes compressor types and their typical characteristics?
  • A decrease in superheat causes the TXV to begin to
  • Fan airflow pressures are usually measured in...
  • A liquid receiver is used to
  • What is the typical target superheat for common residential systems?
  • Why is refrigerant-oil compatibility important and what steps should you take when replacing oil?
  • Which statement is not true about a capillary tube metering device?
  • A compressor that has a broken Reed valve will cause these symptoms...
  • A partially clogged capillary tube can cause which evaporator condition?
  • An inefficient compressor is usually indicated by ___ head pressure and ___ suction pressure.
  • Which statement best describes a thermostatic expansion valve and a capillary tube in terms of control, efficiency, and operating range?
  • Capillary tube metering devices are best described as
  • Which of the following types of air conditioning compressors is most energy efficient?
  • Which symptom would indicate an oil-logged condenser?
  • A compound pressure gauge measures
  • Which of the following cannot be used as a low ambient temperature control?
  • A decrease in superheat causes the TXV to begin to
  • A low refrigerant charge in a system with an AXV metering device will result in which condition?
  • What is the primary purpose of a service valve in a refrigeration system?
  • What is oil return and how do suction-side components help ensure it?
  • When connecting copper to steel, the recommended brazing filler alloy is a...
  • Which statement best describes the regulatory guidance for reclaim, recycling, and recap of refrigerants?
  • While troubleshooting a residential split system, the service technician finds low operating pressures and low system amperage draw. This could be an indication of:
  • Air or other noncondensable gases in a capillary tube air conditioning system will cause these symptoms.
  • What does the sensing bulb of a TXV/EVV do and where should it be placed?
  • A liquid to suction heat exchanger is often used to...
  • What is the role of an accumulator in the oil return path?
  • When an AXV is used as a metering device, a low refrigerant charge will cause...
  • Which term describes heat transfer during vaporization?
  • In a DX evaporator system, the refrigerant enters the evaporator as
  • To remove as much moisture as possible from a system, what evacuation procedure is recommended?
  • Why is proper documentation of service data and test results important in refrigeration work?
  • In a direct expansion evaporator system, the refrigerant entering the evaporator is best described as
  • When using an electronic leak detector, at what rate should the sensor probe be moved to survey for leaks?
  • A restriction in the metering device can cause which evaporator condition?
  • For an R410A system with a gauge reading of 124 psig and a suction line temperature of 54°F, what is the operating superheat?
  • What is the recommended evacuation procedure to remove moisture from a system?
  • A refrigerant overcharge in a capillary tube air conditioning system will cause these symptoms...
  • Which of the following best describes the typical relationship between evaporator outlet and inlet temperatures in a TXV system?
  • Three basic types of condensers are water cooled, air cooled, and ___ cooled.
  • Which is not a thermodynamic property of refrigerants?
  • An overcharge of refrigerant will cause which condition?
  • An overcharge of refrigerant will cause:
  • What is a microchannel coil and what are its advantages and maintenance considerations?
  • A low pressure cut-off switch is used to...
  • The heat removed from the refrigerant by the condenser is which type of heat?
  • Which condition is commonly associated with a low refrigerant charge in the system?
  • What is a typical result of an incorrect refrigerant charge?
  • The main function of the condenser is
  • An accumulator is used to
  • A dirty evaporator in an air conditioning system will cause these symptoms...
  • An air conditioning system that is oversized can cause...
  • Which of the following describes proper PPE and lockout/tagout practices when servicing refrigeration equipment?
  • A centrifugal compressor is typically associated with which of the following characteristics?
  • A residential split system had a compressor replaced last week; now the unit is not cooling properly. The evaporator seems starved of refrigerant. The liquid line is sweating where it leaves the dryer. This is most likely the result of:
  • The heat removed from the refrigerant by the condenser is
  • What pressure is sensed by the TXV's sensing bulb?
  • In the evaporator, the refrigerant absorbs latent heat from the space which causes it to
  • How is superheat defined?
  • During condensation, the refrigerant releases heat to the surroundings.
  • The temperature rise method of determining air volume can be used on:
  • Which safety attribute is a key reason for keeping refrigerant cylinders upright and away from heat?
  • Which option is NOT a TXV operating pressure?
  • In the condenser example, the BTU transferred by the water is
  • A low refrigerant charge in an air conditioning system will cause these symptoms...
  • Which practice helps ensure the correct oil type is used after service?
  • The temperature rise method of determining air volume is applicable to which equipment?
  • Which condition is typically observed when a TEV bulb becomes detached from the suction line?
  • Why should nitrogen be used to pressurize or purge a system prior to leak testing and brazing?
  • Subcooling is defined as which of the following?
  • Zero psig is the same as which condition?
  • What is the purpose of a liquid-line filter-drier and where should it be installed?
  • Which method can be used for leak detection with all high-pressure refrigerants?
  • Before leak testing, what is a critical safety/environmental precaution you should take?
  • Which electrical checks help prevent compressor overload?
  • Before opening a vapor compression system for service, what must be done with the refrigerant?
  • In an air conditioning system that uses a thermostatic expansion valve, the temperature of the evaporator outlet will usually be...
  • What is the purpose of the metering device in a vapor-compression refrigeration cycle?
  • List common reasons for a system to display low refrigerant charge and how to verify each.
  • A OF a TEV bulb that has detached from the suction line will typically produce which pressure condition?
  • What steps should you take to verify system cleanliness after brazing or major repairs?
  • In a basic vapor-compression refrigeration cycle, which component is responsible for raising the pressure and temperature of the refrigerant vapor?
  • The AXV best suited for operation under which condition?
  • Why is unobstructed condenser airflow crucial?
  • Compare R-407C and R-404A in terms of typical applications and operating temperatures.
  • Which of the following is a typical sign of a malfunctioning TXV/EEV?
  • A TEV bulb which becomes detached from the suction line will cause these symptoms...
  • At a residential service call with no cooling and unit completely out of refrigerant, the technician decides to use a trace amount of refrigerant and ___ in order to pressurize the system
  • In a water-cooled condenser scenario, 10 lbs of refrigerant loses 20 BTU per lb, and 10 lbs of water passes through with the entering water at 80°F. What is the water leaving temperature?
  • What is the function of a receiver in a refrigeration system, and when is a receiver used?
  • When topping off an operating system containing a blended refrigerant, how should the refrigerant be introduced?
  • Which maintenance step helps prevent compressor overload in hot weather conditions?
  • When a TEV or a capillary tube is used as a metering device, a low refrigerant charge will cause...
  • Which statement about capillary tubes is true?
  • Why is adequate airflow across the evaporator essential, and what are common causes of restricted airflow?
  • Electric defrost and hot-gas defrost cycles operate and what are practical differences?
  • When charging a system, how do you decide whether to use the superheat method or the subcooling method?
  • Which component is primarily part of the high-side circuit in a typical refrigeration system?
  • What maintenance consideration is particularly important for microchannel coils?
  • Which statement correctly describes the evaporator pressure regulating valve (EPR)?
  • Solid contaminants such as sludge and carbon, from a severe hermetic compressor motor burnout are best removed...
  • After installing a new system, describe a standard charging procedure using the superheat method and what data to record.
  • Distinguish between refrigerant reclaim, recycling, and recap, and describe when each is required.
  • Liquid line sweating near the dryer is most likely caused by:
  • What are common methods for leak testing refrigerant circuits and what precautions should you take?
  • What type of gauge is used to measure microns?
  • What is a typical purpose of a liquid-to-suction heat exchanger in refrigeration systems?
  • What is the function of the condenser in a vapor-compression refrigeration system?
  • The main function of the condenser in a refrigeration system is to remove heat from the refrigerant.
  • Back seating a two-way service valve results in which condition?
  • The temperature at which moisture will start to condense from the air is called
  • Which of the following statements best describes the evaporator airflow requirement for residential AC?
  • If the line temperature is 70°F and the pressure corresponds to a saturated suction temperature of 42°F, what is the system's superheat?
  • Which statement defines the dew point temperature?
  • Which statement best describes the reason for slight suction-line superheat in a refrigeration system?
  • Refrigerant R-134a vapor enters the condenser at 124 psig, 100°F and leaves at 80°F. Its pressure will be approximately...
  • Provide approximate normal high-side and low-side pressure ranges for R-410A at typical outdoor temperatures.
  • What is the generally accepted range for evaporator air flow in cfms per ton of residential air conditioning?
  • Which statement best contrasts electric defrost and hot-gas defrost in terms of heat source and typical use?
  • What is the maximum operating pressure setting for an acetylene torch?
  • Which of the following is not a symptom of a hermetic system that is low on refrigerant?
  • Which loads should the evaporator coil design primarily address?
  • Which methods remove moisture from a refrigeration system?
  • What are safe practices for handling refrigerant cylinders, including weight checks and storage?
  • The clearance space in a reciprocating compressor
  • Zero psia is:
  • After observing a liquid line leak repair and system recharge, a noisy, hot compressor likely indicates which problem?
  • When mounting a TXV sensor bulb, which of the following is NOT true
  • Which factor does a TXV primarily respond to in regulating refrigerant flow?
  • A refrigerant gives up heat when:
  • A customer complains their air conditioning system runs constantly but does not cool well, the suction line is very cold and the compressor is sweating. The most likely cause is:
  • Which device is used to prevent evaporator pressure from falling below a set limit?
  • Which statement about capillary tubes is true?
  • Which of the following is a common cause of compressor short cycling and how would you diagnose it?
  • In an air conditioning system that uses a TXV, the evaporator outlet temperature is usually
  • In testing the efficiency of a water-cooled condenser, the refrigerant condensing temperature should be no more than approximately how many degrees higher than the leaving water temperature?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy